Product was successfully added to your shopping cart.

ABL-8A

Model: ABL-8
Type: All -in one, microprocessor controlled
Test Standards: ISO 13736/ IP170, ISO 1516, ISO 1523
Measuring Range: +10°C to +110°C at room temperature of 10 to 30°C
Measurement Modes: ISO13736 Normal, ISO13736 SPE (search), ISO13736 Rapid, ISO1516, ISO1523, and User Custom
Bath: Metal Block
Sample Cooling/Heating: By Peltier Device
Display: 5.7 inch (117 x 88mm) color LCD with LED back light
Stirring: 0, 30 rpm (selectable)
Temperature Sensor: PT-100 in stainless steel sheath
Flash Detector: CRC Thermocouple
Ignition Source: Gas ignition with automatic lighting or electric ignition. Interchangeable
Barometric Correction: Automatic correction by built-in barometric pressure sensor
I/O Port: 1x RS-232C (for PC or Optional Printer); 1x USB channel (for USB keyboard or USB Flash Memory)
Safety Shutdown: Automatically shuts off and the problem is reported by buzzer and display, in case: (a) EFP+10 oC or 70 oC (ISO13736)110 oC(ISO1516,ISO1523) is reached, (b) temperature sensor is found defective, (c) flash detector is found defective, (d) thermofuse is blown, (e) electric Igniter is blown, (f) built-in battery is found drained out, (g) test cover is not set in place, (h)control computer runs away (no display)
Gas Supply: (When Gas Ignition is used), LP gas or natural gas (Max. pressure:10kPa)
Power Supply: 100/120VAC or 220/240 VAC, 50/60Hz
Power Consumption: 250VA MAX.
Electricity Consumption: 30Wh for 1 test (about 30 min), 11.34gCO2 (@ 0.378kgCO2/1kWh)
Ambient Temp. Range: 10°C to 35°C
Dimensions & Weight: 230mm (W) x 470mm (D) x 390mm (H) 16kg

IQ/OQ/PQ Qualification: Yes, possible

Raspoloživost: Na lageru

Detalji

Automated Cleveland Open Cup Flash Point Tester
ACO-8/8AS

Based on 45 years of experience in manufacturing automated flash point testers, innovative 8th generation series has been released.

The theme of the 8th generation is "Ergonomic, Versatile and Premium"

Ergonomically designed display and switches for high visibility for everybody (universal design) and intuitive operation.
Enhanced versatility including USB port for optional flash memory or key board, password protection and data storage (200 tests)
All-in-one chassis design: compact, light-weight and premium exterior design.
Further improved Swing Arm assembly for easy setting and cleaning:
After inserting the test cup in the instrument, just lower the swing arm assembly onto the test cup to set all the necessary components for the test, including the ignition source, temperature sensor, flash detector and stirrer (in case of abl-8 and apm-8). After the test, tilt the arm to the complete upright position for easy cleaning.

ACO-8/8AS Automated Cleveland Open Cup Flash Point Tester
Model aco-8 is an automated Cleveland Open Cup (COC) flash & fire point tester.

Gas test flame is ignited automatically.

Fire point is determined automatically when sustaining combustion has been detected for 5 sec.

Fire containment by a metallic lid covers the test cup automatically when a sustained fire is detected.

Model aco-8as is for testing bituminous materials.